DOM Tube RFQ – Worked Example: OD, ID, Wall, Tolerances & Condition

A DOM (drawn over mandrel) tube enquiry that lists OD, ID and wall, with no tolerances or condition, cannot be quoted correctly. This worked example from ASC LLP, Mumbai, shows how to turn a part requirement into an ASTM A513 Type 5 DOM tube RFQ: which two dimensions to specify, how the tolerances stack, and what else the order must state.

Download the one-page DOM tube RFQ worksheet (PDF). For grades and sizes, see our A513 1020 DOM tubes page; for how DOM tube is made, see our DOM manufacturing article.

The Rule: Specify Only Two of OD, ID and Wall

Mechanical tubing tolerances can be applied to only two of the three cross-section dimensions at the same time: OD × wall, OD × ID, or ID × wall. The third dimension is then a reference value, and its actual variation follows from the other two. Therefore, the first decision on any DOM RFQ is which two dimensions matter to the part.

DOM tube RFQ example

Which Two Dimensions Should You Order?

If the part needs… Order by Reference dimension
A controlled outside fit and pressure or strength wall OD × wall ID
A bore fit, for example a bushing or cylinder bore OD × ID Wall
An inside fit with a controlled wall ID × wall OD

Tolerances Used in This Example

Item Published A513 Type 5 value (inches)
OD tolerance, 1.700 – 2.099″ OD +0.006 / −0.000
ID tolerance, same OD range +0.000 / −0.006
Wall tolerance, 0.120″ wall, OD over 1⅞ to 3¾” ±0.003
Additional ovality, OD up to 2″ 0.010 (mean OD must still be within tolerance)

These values are taken from published ASTM A513 Type 5 DOM tolerance tables. However, tolerances depend on size and wall, so always confirm them against the current A513 edition or the mill’s tolerance sheet for your exact size.

A513 DOM tubes
DOM mechanical tubing

Worked Example – Option A: Order by OD × Wall

Part need: a sleeve with 2.000″ OD and nominal 0.120″ wall (50.80 × 3.05 mm), where the OD fits a housing.

  • OD: 2.000″ +0.006 / −0.000, so 2.000 – 2.006″.
  • Wall: 0.120″ ±0.003, so 0.117 – 0.123″.
  • Resulting ID (reference): smallest = 2.000 − 2 × 0.123 = 1.754″; largest = 2.006 − 2 × 0.117 = 1.772″.

In other words, the ID can vary by 0.018″, three times the 0.006″ ID tolerance. That is acceptable for a clearance bore, but not for a precision bore fit.

Worked Example – Option B: Order by OD × ID

Part need: the same tube, but now the ID must fit a 1.760″ shaft or piston, so the bore is critical.

  • OD: 2.000″ +0.006 / −0.000, so 2.000 – 2.006″.
  • ID: 1.760″ +0.000 / −0.006, so 1.754 – 1.760″.
  • Resulting average wall (reference): (2.000 − 1.760) ÷ 2 = 0.120″ to (2.006 − 1.754) ÷ 2 = 0.126″.

Now the bore is controlled; however, the wall is no longer guaranteed at any single point, because eccentricity is not limited by OD and ID tolerances alone. If both a precise bore and a minimum wall are needed, state a minimum wall on the drawing or order material oversize for machining.

Allow for Ovality and Machining

  • Ovality: a 2″ DOM tube may be up to 0.010″ out of round, as long as the mean OD is within tolerance; therefore, a tight press fit may need sizing or machining.
  • Machining stock: if the part will be turned or honed, add stock to both OD and ID, so the finished size is inside the tube tolerance band.
  • Length: state cut length and length tolerance, for example 300 mm +2 / −0 mm.
  • Measurement: diameters are measured at least 2″ (50 mm) from the tube ends.

Complete DOM Tube Order Checklist

Item What to state Example
Specification and type ASTM A513, Type 5 (DOM) ASTM A513 Type 5
Grade 1020, 1026 or other 1026
Condition As drawn, stress relieved or normalized Stress relieved
Dimensions Two of OD, ID and wall, with tolerances OD 2.000″ × ID 1.760″
Length Random or cut length, with tolerance 300 mm +2 / −0
Tests and documents Certificate type; extra tests if needed EN 10204 3.1

The condition matters because cold drawing raises strength but lowers ductility. As a result, as-drawn, stress-relieved and normalized tubes of the same grade have different properties, so the condition should match the drawing.

Sample RFQ Line

Illustrative example, not a customer order:

500 pcs DOM tube, ASTM A513 Type 5, grade 1026, stress relieved; OD 2.000″ +0.006 / −0.000 × ID 1.760″ +0.000 / −0.006 (wall reference); cut length 300 mm +2 / −0 mm; ends square cut and deburred; EN 10204 3.1 certificate.

Common Mistakes

  • All three dimensions toleranced: OD, ID and wall cannot all be guaranteed, so one becomes a reference.
  • No condition: consequently, as-drawn tube arrives when the part needed stress-relieved tube for bending.
  • Ovality ignored: a press fit fails even though the mean OD is in tolerance.
  • No machining allowance: finally, the finished bore cannot be cleaned up within the wall.

Related DOM Tube Pages

For grades and sizes, see A513 1020 DOM tubes, grade 1026 tubes, 1015 tubes and welded 1020 tubes. In addition, see our DOM tubes overview.

Send Your DOM Tube RFQ to ASC LLP

  • Checked enquiries: first, we check which two dimensions you need and confirm tolerances for your size before quoting.
  • Correct condition: as-drawn, stress relieved or normalized, matched to your part.
  • Cut lengths: moreover, tubes can be cut to length and deburred.

To get a quotation, please send your RFQ with the drawing or this worksheet completed.

Frequently Asked Questions – DOM Tube RFQs

Can I specify OD, ID and wall tolerances on a DOM tube?

No. In short, tolerances apply to only two of the three dimensions; the third is a reference value.

When should DOM tube be ordered by OD × ID?

When the bore is critical, for example for a bushing, sleeve or cylinder. The wall then becomes a reference value.

What is the OD tolerance of a 2″ DOM tube?

Published A513 Type 5 tables give +0.006 / −0.000″ for 1.700–2.099″ OD, but always confirm for your exact size.

Does ovality count in the DOM tolerance?

Additional ovality is allowed, for example up to 0.010″ for tubes up to 2″ OD, provided the mean OD is within tolerance.

What condition should DOM tube be ordered in?

As drawn, stress relieved or normalized, depending on the part. Stress-relieved or normalized tube is easier to bend and form.

Which ASTM specification covers DOM tube?

ASTM A513 Type 5 covers drawn-over-mandrel carbon steel mechanical tubing, commonly in grades 1020 and 1026.

Global Supply

ASC LLP supplies DOM and mechanical tubing from Mumbai to customers in India, the Middle East, Europe, Africa, the Americas and South-East Asia. To get a prompt quotation, simply send your completed worksheet.

Product supply – ASC LLP

Countries We Export To

UNITED STATES, EUROPE, UK, UAE, SAUDI ARABIA, OMAN, KUWAIT, JORDAN, QATAR, INDONESIA, MALAYSIA, BRAZIL, SPAIN, ITALY, FRANCE, GERMANY, BAHRAIN, SRI LANKA, AZERBAIJAN, AUSTRALIA, AUSTRIA, PHILIPPINES, TURKEY, RUSSIA, IRAN, IRAQ, CANADA, KOREA, JAPAN, YEMEN, FINLAND, ZIMBABWE, HUNGARY, PORTUGAL, VIETNAM, MOROCCO, THAILAND, SOUTH AFRICA, MEXICO, SINGAPORE, GREECE, KUWAIT, POLAND, NEW ZEALAND, SWEDEN, SWITZERLAND, BELGIUM, BHUTAN, BANGLADESH, TAIWAN, ROMANIA, CAMBODIA, KAZAKHSTAN, AFGHANISTAN.

Follow us on: